Go top
Conference paper information

Indirect-field-orientated control of an asynchronous generator with rotor-resistance adaptation based on a reference model

P.L. Roncero-Sánchez, A. García-Cerrada, V. Feliú

15th IFAC World Congress on Automatic Control, Barcelona (Spain). 21-26 July 2002


Summary:

This paper studies in detail a method for rotor-resistance adaptation for indirect-field orientated control of induction generators based on the reactive-power reference model. First of all, it will be shown how the adaptation procedure can be made independent of stator frequency and load torque. Secondly, the stability of the adaptation procedure will be demonstrated rigorously by means of Lyapunov theorem. Simulation results using data from two di®erent machines will be presented to validate the main contributions. Finally, the sensitivity of the algorithm to errors in other machine parameters will be investigated.


Keywords: Field-Orientated Control, Induction Motors, MRAS


DOI: DOI icon https://doi.org/10.3182/20020721-6-ES-1901.01210

Published in IFAC Proceedings Volumes, vol: 35, pp: 353-358, ISSN: 1474-6670

Publication date: 2002-12-31.



Citation:
P.L. Roncero-Sánchez, A. García-Cerrada, V. Feliú, Indirect-field-orientated control of an asynchronous generator with rotor-resistance adaptation based on a reference model, 15th IFAC World Congress on Automatic Control, Barcelona (Spain). 21-26 July 2002. In: IFAC Proceedings Volumes, vol. 35, nº. 1, ISSN: 1474-6670


    Research topics:
  • *Power Electronics and Control Systems

Request Request the document to be emailed to you.