Ir arriba
Información del artículo

A parametric study of hard tissue injury prediction using finite elements: consideration of geometric complexity, subfailure material properties, CT-thresholding and element characteristics

C. Arregui-Dalmases, E. Pozo de Dios, S. Duprey, F.J. López-Valdés, A. Lau, D. Subit, R. W. Kent

Traffic Injury Prevention Vol. 11, nº. 3, pp. 286 - 293

Resumen:

Objective:

The objectives of this study were to examine the axial response of the clavicle under quasistatic compressions replicating the body boundary conditions and to quantify the sensitivity of finite element–predicted fracture in the clavicle to several parameters.

Methods:

Clavicles were harvested from 14 donors (age range 14–56 years). Quasistatic axial compression tests were performed using a custom rig designed to replicate in situ boundary conditions. Prior to testing, high-resolution computed tomography (CT) scans were taken of each clavicle. From those images, finite element models were constructed. Factors varied parametrically included the density used to threshold cortical bone in the CT scans, the presence of trabecular bone, the mesh density, Young's modulus, the maximum stress, and the element type (shell vs. solid, triangular vs. quadrilateral surface elements).

Results:

The experiments revealed significant variability in the peak force (2.41 ± 0.72 kN) and displacement to peak force (4.9 ± 1.1 mm), with age (p < .05) and with some geometrical traits of the specimens. In the finite element models, the failure force and location were moderately dependent upon the Young's modulus. The fracture force was highly sensitive to the yield stress (80–110 MPa).

Conclusions:

Neither fracture location nor force was strongly dependent on mesh density as long as the element size was less than 5 × 5 mm2. Both the fracture location and force were strongly dependent upon the threshold density used to define the thickness of the cortical shell.


Palabras Clave: Finite element modeling, Fracture prediction, Clavicle, Side impact, Sensitivity study


Índice de impacto JCR y cuartil WoS: 1,401 (2010); 1,600 - Q3 (2023)

Referencia DOI: DOI icon https://doi.org/10.1080/15389581003709902

Publicado en papel: Junio 2010.

Publicado on-line: Junio 2010.



Cita:
C. Arregui-Dalmases, E. Pozo de Dios, S. Duprey, F.J. López-Valdés, A. Lau, D. Subit, R. W. Kent, A parametric study of hard tissue injury prediction using finite elements: consideration of geometric complexity, subfailure material properties, CT-thresholding and element characteristics. Traffic Injury Prevention. Vol. 11, nº. 3, pp. 286 - 293, Junio 2010. [Online: Junio 2010]


    Líneas de investigación:
  • *Sistemas Mecánicos: Mecánica estructural, elementos de máquinas, prototipado rápido, metrología dimensional

pdf Previsualizar
pdf Solicitar el artículo completo a los autores